Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 349
53-1002448-01
FW-1051
45
Recommended
Action
Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0
(Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates.
Severity WARNING
FW-1051
Message <timestamp>, [FW-1051], <sequence-number>,, WARNING, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high
boundary. High voltages indicate possible hardware failures.
Recommended
Action
Frequent voltage fluctuations indicate that the SFP is deteriorating. Replace the SFP.
Severity WARNING
FW-1052
Message <timestamp>, [FW-1052], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity INFO
FW-1053
Message <timestamp>, [FW-1053], <sequence-number>,, WARNING, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause Indicates that the value of the small form-factor pluggable (SFP) Power on Hours has fallen below
the low boundary.
Recommended
Action
Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0
(Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates.
Severity WARNING