Message <timestamp>, [FW-1160], <sequence-number>,, INFO, <system-name>, <Port Name>,
<Label>, value has changed(High=<High value>, Low=<Low value>). Current value is
<Value> <Unit>.
Probable Cause Indicates that the number of link failures that the port experiences has changed. Link loss errors
occur when a link experiences a loss of signal and fails. Both physical and hardware problems can
cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for
concurrent loss of synchronization errors and, if applicable, troubleshoot them.
Recommended
Action
Check both ends of your cable connection. Verify that the cable and small form-factor pluggables
(SFPs) are not faulty.
Losses of synchronization commonly causes link failures. If you receive concurrent loss of
synchronization errors, troubleshoot the loss of synchronization.
Severity INFO
FW-1161
Message <timestamp>, [FW-1161], <sequence-number>,, INFO, <system-name>, <Port Name>,
<Label>, is below low boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the number of link failures that the port experiences has fallen below the low
boundary. Link loss errors occur when a link experiences a loss of signal and fails. Both physical
and hardware problems can cause link loss errors. Link loss errors frequently occur due to a loss of
synchronization. Check for concurrent loss of synchronization errors and, if applicable,
troubleshoot them. A low number of link loss errors means that the switch is functioning normally.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity INFO
FW-1162
Message <timestamp>, [FW-1162], <sequence-number>,, WARNING, <system-name>, <Port Name>,
<Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the number of link failures that the port experiences has risen above the high
boundary. Link loss errors occur when a link experiences a loss of signal and fails. Both physical
and hardware problems can cause link loss errors. Link loss errors frequently occur due to a loss of
synchronization. Check for concurrent loss of synchronization errors and, if applicable,
troubleshoot them.
Recommended
Action
Check both ends of your cable connection. Verify that the cable and small form-factor pluggables
(SFPs) are not faulty.