Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 399
53-1002448-01
FW-1425
45
FW-1425
Message <timestamp>, [FW-1425], <sequence-number>,, INFO, <system-name>, Switch status
changed from <Bad state> to HEALTHY.
Probable Cause Indicates that the switch status has changed to a healthy state. This occurred because a policy is
no longer violated.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity INFO
FW-1426
Message <timestamp>, [FW-1426], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor Power supply: <Number Bad> bad, <Number Missing>
absent.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty or missing power supplies is greater than or equal to the policy set by the
switchStatusPolicySet command.
Recommended
Action
Replace the faulty or missing power supply.
Severity WARNING
FW-1427
Message <timestamp>, [FW-1427], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor Power supply: <Number Bad> bad.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty power supplies is greater than or equal to the policy set by the switchStatusPolicySet
command.
Recommended
Action
Replace the faulty power supply.
Severity WARNING
FW-1428
Message <timestamp>, [FW-1428], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor Power supply: <Number Missing> absent.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet
command.