Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

422 Fabric OS Message Reference
53-1002448-01
HAM-1005
46
Giveup Master:SYSM
CP Faulty:SYSM
FirmwareDownload
ConfigDownload:MS
ChangeWWN:EM
Reboot:WebTool
Fastboot:WebTool
Software Fault:Software Watchdog
Software Fault:Kernel Panic
Software Fault:ASSERT
Reboot:SNMP
Fastboot:SNMP
Reboot
Chassis Config
Reboot:API
Reboot:HAM
EMFault:EM
Recommended
Action
Execute the errShow command on both the CPs to view the error log for additional messages that
may indicate reason for the switch restart.
Severity INFO
HAM-1005
Message <timestamp>, [HAM-1005], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,
<system-name>, HeartBeat Miss reached threshold.
Probable Cause Indicates that the active CP Ethernet Media Access Controller (EMAC) or the standby CP is down.
The active CP will run a diagnostic test on the EMAC and will wait for the standby CP to reset if it is
down.
Recommended
Action
No action is required.
Severity INFO
HAM-1006
Message <timestamp>, [HAM-1006], <sequence-number>, SLOT cp-slpt-number | FFDC | CHASSIS,
FFDC, CRITICAL, <system-name>, EMAC controller for Active CP is BAD.
Probable Cause Indicates that the local EMAC on the active CP has been marked BAD as determined by the
diagnostic test run by the HAM module.