Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 427
53-1002448-01
Chapter
47
HAMK System Messages
HAMK-1001
Message <timestamp>, [HAMK-1001], <sequence-number>, SLOT cp-slot-number | CHASSIS, FFDC,
CRITICAL, <system-name>, Warm recovery failed.
Probable Cause Indicates that the switch failed during the warm recovery.
Recommended
Action
This event triggers a switch restart automatically and attempts a cold recovery. Execute the
supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave
command and contact your switch service provider.
Severity CRITICAL
HAMK-1002
Message <timestamp>, [HAMK-1002], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,
<system-name>, Heartbeat down.
Probable Cause Indicates that the active control processor (CP) blade determined that the standby CP blade is
down. This can be a result of a user-initiated action such as firmware download, the standby CP
blade being reset or removed, or an error in the standby CP blade.
Recommended
Action
Monitor the standby CP blade for a few minutes. If this message is due to a standby CP restart, the
message HAMK-1003 will display after the standby CP is restarted.
If the standby CP does not connect to the active CP after 10 minutes, restart the standby CP blade
by ejecting the blade and reseating it.
Severity INFO
HAMK-1003
Message <timestamp>, [HAMK-1003], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,
<system-name>, Heartbeat up.
Probable Cause Indicates that the active CP blade detected the standby CP blade. This message indicates that the
standby CP blade is available to take over in case a failure happens in the active CP blade. Typically,
this message is displayed when the standby CP blade restarts.
Recommended
Action
No action is required.
Severity INFO