Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 437
53-1002448-01
HIL-1401
48
If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty
behavior. Replace the switch because the fan is not field-replaceable.
Severity INFO
HIL-1401
Message <timestamp>, [HIL-1401], <sequence-number>,, WARNING, <system-name>, One fan FRU
missing. Install fan FRU immediately.
Probable Cause Indicates that one fan field-replaceable unit (FRU) has been removed.
Recommended
Action
Install the missing fan FRU.
Severity WARNING
HIL-1402
Message <timestamp>, [HIL-1402], <sequence-number>,, WARNING, <system-name>, Two fan FRUs
missing. Install fan FRUs immediately.
Probable Cause Indicates that two fan field-replaceable units (FRUs) have been removed.
Recommended
Action
Install the missing fan FRUs immediately.
Severity WARNING
HIL-1403
Message <timestamp>, [HIL-1403], <sequence-number>,, WARNING, <system-name>, All fan FRUs
missing. Install fan FRUs immediately.
Probable Cause Indicates that all fan field-replaceable units (FRUs) have been removed.
Recommended
Action
Install the missing fan FRUs immediately.
Severity WARNING
HIL-1404
Message <timestamp>, [HIL-1404], <sequence-number>,, WARNING, <system-name>, <count> fan
FRUs missing. Install fan FRUs immediately.
Probable Cause Indicates that one or more fan field-replaceable units (FRUs) have been removed.