Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

438 Fabric OS Message Reference
53-1002448-01
HIL-1501
48
Recommended
Action
Install the missing fan FRUs immediately.
Severity WARNING
HIL-1501
Message <timestamp>, [HIL-1501], <sequence-number>,, WARNING, <system-name>, Slot <slot
number>, high temperature (<measured temperature>).
Probable Cause Indicates that the temperature of this blade has risen above the warning threshold.
Recommended
Action
Run the fanShow command to verify all the fans are working properly.
Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Severity WARNING
HIL-1502
Message <timestamp>, [HIL-1502], <sequence-number>, FFDC, CRITICAL, <system-name>, Slot
<slot number>, high temperature (<measured temperature>). Unit will be shut down
in 2 minutes if temperature remains high.
Probable Cause Indicates that the temperature of this blade has risen above the critical threshold. This usually
follows a high-temperature message.
Recommended
Action
Run the fanShow command to verify all the fans are working properly.
Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
If the message persists, replace the blade.
Severity CRITICAL
HIL-1503
Message <timestamp>, [HIL-1503], <sequence-number>, FFDC, CRITICAL, <system-name>, Slot
<slot number>, unit shutting down.
Probable Cause Indicates that the temperature of this blade has been above the maximum threshold for at least
two minutes. The blade is shut down to prevent damage. This usually follows a high-temperature
warning message.
Recommended
Action
Run the fanShow command to verify all the fans are working properly.