Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 439
53-1002448-01
HIL-1504
48
Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
If the message persists, replace the faulty blade.
Severity CRITICAL
HIL-1504
Message <timestamp>, [HIL-1504], <sequence-number>,, INFO, <system-name>, System within
normal temperature specifications (<measured temperature> C).
Probable Cause Indicates that temperatures in the system have returned to normal.
Recommended
Action
No action is required.
Severity INFO
HIL-1505
Message <timestamp>, [HIL-1505], <sequence-number>,, WARNING, <system-name>, High
temperature (<measured temperature> C) fan speed increasing per environmental
specifications.
Probable Cause Indicates that temperatures in the system have risen above the warning threshold and the fan
speed is increased.
Recommended
Action
Run the fanShow command to verify all the fans are working properly.
Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Severity WARNING
HIL-1506
Message <timestamp>, [HIL-1506], <sequence-number>, FFDC, CRITICAL, <system-name>, High
temperature (<measured temperature> C) exceeds system temperature limit. System
will shut down within 2 minutes.
Probable Cause Indicates that temperatures in the system have risen above the critical threshold.
Recommended
Action
Run the fanShow command to verify that all fans are working properly. Replace any deteriorating
fan field-replaceable units (FRUs).