460 Fabric OS Message Reference
53-1002448-01
ICPD-1005
55
Recommended
Action
Enable the iSNS Client service on a single switch in the fabric using the fosConfig command. Refer
to the Fabric OS Command Reference for more information on this command.
Severity WARNING
ICPD-1005
Message <timestamp>, [ICPD-1005], <sequence-number>,, WARNING, <system-name>, iSCSI
configuration between local switch (<local domain id>) and peer (<peer domain id>)
is out of sync. iSCSI login is not allowed.
Probable Cause Indicates that iSCSI switches in the fabric have different configurations in AUTH, VT, or DD.
Recommended
Action
Synchronize the configuration in the fabric using the iscsiCfg command. Refer to the Fabric OS
Command Reference for more information on this command.
Severity WARNING
ICPD-1006
Message <timestamp>, [ICPD-1006], <sequence-number>,, INFO, <system-name>, iSCSI service
is <status> on the switch.
Probable Cause Indicates the iSCSI service is enabled or disabled on the switch.
Recommended
Action
No action is required.
Severity INFO
ICPD-1007
Message <timestamp>, [ICPD-1007], <sequence-number>,, INFO, <system-name>, iSNSC service
is <status> on the switch.
Probable Cause Indicates the iSNSC service is enabled or disabled on the switch.
Recommended
Action
No action is required.
Severity INFO
ICPD-1008
Message <timestamp>, [ICPD-1008], <sequence-number>,, INFO, <system-name>, iSCSI switch
(<domain id>) is <status>.
Probable Cause Indicates the iSCSI switch is reachable or unreachable.