Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 503
53-1002448-01
Chapter
70
MFIC System Messages
MFIC-1001
Message <timestamp>, [MFIC-1001], <sequence-number>,, ERROR, <system-name>, Failure at
sysmod_scn registry rc= <failure reason>.
Probable Cause Indicates that the system is temporarily out of resources.
Recommended
Action
This error is often transitory.
Execute the reBoot or haFailover commands (if applicable). If the problem persists, execute the
supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave
command and contact your switch service provider.
Severity ERROR
MFIC-1002
Message <timestamp>, [MFIC-1002], <sequence-number>,, INFO, <system-name>, Chassis FRU
header not programmed for switch NID, using defaults (applies only to FICON
environments).
Probable Cause Indicates that the custom switch node identification data (NID) fields are not programmed in
nonvolatile storage. The default values are used. The switch NID is used only in the following Single
Byte (SB) Extended Link Services (ELS) frames:
Request Node Identification Data (RNID)
Registered Link Incident Record (RLIR)
The use of SB-3 link incident registration and reporting is typically limited to Fibre Connectivity
(FICON) environments.
Recommended
Action
No action is required if SB-3 link incident registration and reporting is not used by the host or if
default values are desired for the switch node descriptor fields.
Severity INFO