Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

512 Fabric OS Message Reference
53-1002448-01
MS-1009
73
If the error persists, check the available memory on the switch using the memShow command.
Severity ERROR
MS-1009
Message <timestamp>, [MS-1009], <sequence-number>,, ERROR, <system-name>, RLIR event.
Switch Port ID is <port number> (<PID (hex)>). Device Port Tag is <port tag>.
<message text>.
Probable Cause Indicates a registered link incident record (RLIR) has been generated for one of the actions
indicated by the <message>.
The following messages will be displayed:
Exceeded bit error rate threshold
Loss of signal or synchronization
Not operational seq. recognized
Primitive sequence timeout
Unrecognized link incident
Recommended
Action
Persistent RLIR incidents are likely the result of SAN hardware problems such as bad cables or
small form-factor pluggables (SFPs). It may be necessary to replace hardware if these messages
persist.
Severity ERROR
MS-1021
Message <timestamp>, [MS-1021], <sequence-number>,, ERROR, <system-name>, MS WARMBOOT
failure(FSS_MS_WARMINIT failed. Reason=<failure reason>).
Probable Cause Indicates the Fabric OS state synchronization (FSS) warm recovery failed during the WARM INIT
phase of a reboot.
Recommended
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
MS-1022
Message <timestamp>, [MS-1022], <sequence-number>,, INFO, <system-name>, Management
Server Platform Service <Activated or Deactivated>.
Probable Cause Indicates Management Server Platform Service is being activated or deactivated.