Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

524 Fabric OS Message Reference
53-1002448-01
NS-1011
76
NS-1011
Message <timestamp>, [NS-1011], <sequence-number>,, WARNING, <system-name>, NS has
detected a failover flag disabled TI zone in a base switch <domain id> in fabric
id <fabric id>.
Probable Cause Indicates that a failover flag has disabled TI zone in a base switch fabric.
Recommended
Action
Modify failover flag to enable or remove TI zone with failover flag disabled since the routing may not
be setup correctly.
Severity WARNING
NS-1012
Message <timestamp>, [NS-1012], <sequence-number>,, WARNING, <system-name>, Detected
duplicate WWPN [<WWPN>] - devices removed with PID 0x<existing device PID> and
0x<new device PID>.
Probable Cause Indicates that the devices with the same World Wide Port Name (WWPN) have been removed from
the Name Server database.
Recommended
Action
Administrators should verify the reported devices with a duplicated WWPN.
Severity WARNING