Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

534 Fabric OS Message Reference
53-1002448-01
PDM-1004
79
PDM-1004
Message <timestamp>, [PDM-1004], <sequence-number>,, WARNING, <system-name>, PDM memory
shortage.
Probable Cause Indicates the parity data manager (PDM) process ran out of memory.
Recommended
Action
Reboot or power cycle the switch.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity WARNING
PDM-1005
Message <timestamp>, [PDM-1005], <sequence-number>,, WARNING, <system-name>, FSS register
failed.
Probable Cause Indicates the parity data manager (PDM) failed to register with the Fabos Synchronization Service
(FSS).
Recommended
Action
Run the firmwareDownload command to reinstall the firmware.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity WARNING
PDM-1006
Message <timestamp>, [PDM-1006], <sequence-number>,, WARNING, <system-name>, Too many
files in sync.conf.
Probable Cause Indicates the configuration file sync.conf contains too many entries.
Recommended
Action
Run the firmwareDownload command to reinstall the firmware.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity WARNING
PDM-1007
Message <timestamp>, [PDM-1007], <sequence-number>,, WARNING, <system-name>, File not
created: <file name> errno= <errno>.
Probable Cause Indicates the parity data manager (PDM) process failed to create the specified file.