Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 549
53-1002448-01
Chapter
83
PORT System Messages
PORT-1003
Message <timestamp>, [PORT-1003], <sequence-number>,, WARNING, <system-name>, Port <port
number> Faulted because of many Link Failures
Probable Cause Indicates that the specified port is now disabled because the link on this port had multiple failures
that exceeded an internally set threshold on the port. This problem is typically related to hardware.
Recommended
Action
Check and replace (if necessary) the hardware attached to both ends of the specified port number,
including:
the media (SFPs)
the cable (fiber optic or copper ISL)
the attached devices
When finished checking the hardware, perform the portEnable command to re-enable the port.
Severity WARNING
PORT-1004
Message <timestamp>, [PORT-1004], <sequence-number>,, INFO, <system-name>, Port <port
number> (<port number (hex)>) could not be enabled because it is disabled due to
long distance.
Probable Cause Indicates the specified port is not enabled because other ports in the same group have used the
buffers for this port group. This happens when other ports were configured to be long distance.
Recommended
Action
To enable this port, reconfigure the other E_Ports so they are not long distance or change the other
E_Ports so they are not E_Ports. This will free some buffers and allow this port to be enabled.
Severity INFO
PORT-1005
Message <timestamp>, [PORT-1005], <sequence-number>,, WARNING, <system-name>, Slot <slot
number> port <port on slot> does not support configured L_port. Issue portCfgLport
to clear configuration.
Probable Cause Indicates the specified port is configured to be an L_port, but the port does not support L_port. If
an L_port is connected, then the port will be disabled because the port does not support L_port. If
an E_port or F_port is connected, then the port will not come up since it is configured to be an
L_port.