Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 559
53-1002448-01
Chapter
86
RAS System Messages
RAS-1001
Message <timestamp>, [RAS-1001], <sequence-number>,, INFO, <system-name>, First failure
data capture (FFDC) event occurred.
Probable Cause Indicates that a first failure data capture (FFDC) event occurred and the failure data has been
captured.
Recommended
Action
Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.
Severity INFO
RAS-1002
Message <timestamp>, [RAS-1002], <sequence-number>,, WARNING, <system-name>, First
failure data capture (FFDC) maximum storage size (<log size limit> MB) was
reached.
Probable Cause Indicates that the storage size for FFDC data has reached the maximum.
Recommended
Action
Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.
Severity WARNING
RAS-1004
Message <timestamp>, [RAS-1004], <sequence-number>, FFDC, WARNING, <system-name>,
Software 'verify' error detected.
Probable Cause Indicates an internal software error.
Recommended
Action
Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.
Severity WARNING