Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

572 Fabric OS Message Reference
53-1002448-01
RPCD-1004
90
RPCD-1004
Message <timestamp>, [RPCD-1004], <sequence-number>,, WARNING, <system-name>, Invalid
certificate file. Secure RPCd is disabled.
Probable Cause Indicates the SSL certificate file has been corrupted.
Recommended
Action
To enable RPCD in Secure mode, install a valid SSL certificate in the switch.
Severity WARNING
RPCD-1005
Message <timestamp>, [RPCD-1005], <sequence-number>,, WARNING, <system-name>, Missing
private key file. Secure RPCd is disabled.
Probable Cause Indicates the private key file is missing.
Recommended
Action
Run the pkiCreate command to install a valid private key file.
Severity WARNING
RPCD-1006
Message <timestamp>, [RPCD-1006], <sequence-number>,, WARNING, <system-name>, Permission
denied accessing private key file. Secure RPCd is disabled.
Probable Cause Indicates the private key file configured on the switch could not be accessed because the root did
not have read-level access.
Recommended
Action
Change the file system access level for the private key file and make sure that the root has
read-level access.
Severity WARNING
RPCD-1007
Message <timestamp>, [RPCD-1007], <sequence-number>,, WARNING, <system-name>, Invalid
private file. Secure RPCd is disabled.
Probable Cause Indicates the private key file has been corrupted.
Recommended
Action
Run the pkiCreate command to install a valid private key file.
Severity WARNING