Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 577
53-1002448-01
Chapter
93
SCN System Messages
SCN-1001
Message <timestamp>, [SCN-1001], <sequence-number>, FFDC, CRITICAL, <system-name>, SCN
queue overflow for process
<daemon name>.
Probable Cause Indicates that an attempt to write a state change notification (SCN) message to a specific queue
has failed because the SCN queue for the specified daemon name is full. This might be caused by
the daemon hanging or the system being busy.
Some valid values for daemon name are listed below. For a complete listing, see the Introduction to
this manual.
fabricd
asd
evmd
fcpd
webd
msd
nsd
psd
snmpd
zoned
fspfd
tsd
Recommended
Action
If this message is caused by the system being busy, the condition is temporary.
If this message is caused by a hung daemon, the software watchdog will cause the daemon to
dump the core and reboot the switch. In this case, run the supportSave command to send the core
files using FTP to a secure server location.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity CRITICAL