SEC-1035
94
SEC-1035
Message <timestamp>, [SEC-1035], <sequence-number>,, ERROR, <system-name>, Invalid device
WWN <device WWN>.
Probable Cause Indicates the specified world wide name (WWN) is invalid.
Recommended
Action
Enter the correct WWN value.
Severity ERROR
SEC-1036
Message <timestamp>, [SEC-1036], <sequence-number>,, ERROR, <system-name>, Device name
<device name> is invalid due to a missing colon.
Probable Cause Indicates one or more device names mentioned in the securePolicyCreate or securePolicyAdd
command does not have the colon character (:) as required.
Recommended
Action
Run the secPolicyCreate or secPolicyAdd command with a properly formatted device name
parameter.
Severity ERROR
SEC-1037
Message <timestamp>, [SEC-1037], <sequence-number>,, ERROR, <system-name>, Invalid WWN
format <invalid WWN>.
Probable Cause Indicates the world wide name (WWN) entered in the policy member list had an invalid format.
Recommended
Action
Run the command again using the standard WWN format, 16 hexadecimal digits grouped as eight
colon separated pairs. For example: 50:06:04:81:D6:F3:45:42.
Severity ERROR
SEC-1038
Message <timestamp>, [SEC-1038], <sequence-number>,, ERROR, <system-name>, Invalid domain
<domain ID>.
Probable Cause Indicates an invalid domain ID was entered.
Recommended
Action
Verify that the domain ID is correct. If it is not, then rerun the command using the correct domain
ID.
Severity ERROR