Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 601
53-1002448-01
SEC-1096
94
SEC-1096
Message <timestamp>, [SEC-1096], <sequence-number>,, ERROR, <system-name>, Failed to
delete <policy name> because <reason text>.
Probable Cause Indicates a policy cannot be removed because deleting it would result in invalid security policy
configuration.
Recommended
Action
Verify the security policy configuration requirements and remove any policies that require the policy
you want to remove first.
Severity ERROR
SEC-1097
Message <timestamp>, [SEC-1097], <sequence-number>,, ERROR, <system-name>, Cannot find
<active or defined> policy set.
Probable Cause Indicates the specified policy could not be found.
Recommended
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
SEC-1098
Message <timestamp>, [SEC-1098], <sequence-number>,, ERROR, <system-name>, No <active or
defined> FCS list.
Probable Cause Indicates the specified policy could not be found.
Recommended
Action
Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command
and contact your switch service provider.
Severity ERROR
SEC-1099
Message <timestamp>, [SEC-1099], <sequence-number>,, ERROR, <system-name>, Please enable
your switch before running secModeEnable.
Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.