Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

630 Fabric OS Message Reference
53-1002448-01
SEC-1314
94
SEC-1314
Message <timestamp>, [SEC-1314], <sequence-number>,, ERROR, <system-name>, Reading <IP
Address Description> IP address from EM failed.
Probable Cause Indicates the call to the EM module to retrieve the IP address failed.
Recommended
Action
Restart the system to fix this error. If the problem persists contact your switch service provider.
Severity ERROR
SEC-1315
Message <timestamp>, [SEC-1315], <sequence-number>,, ERROR, <system-name>, <Name of
command > command failed -<List of databases rejecting distribution> db(s)
configured for rejection on this switch
Probable Cause Indicates there was an attempt to distribute databases to a switch that was configured not to
accept distributions from the fabric.
Recommended
Action
Verify the accept distribution configuration for the listed databases. Use the fddCfg command to
verify and correct the configuration if necessary.
Severity ERROR
SEC-1316
Message <timestamp>, [SEC-1316], <sequence-number>,, WARNING, <system-name>, <Policy
Name> policy WWN List is conflicting with domain <Domain Number>.
Probable Cause Indicates the newly added switches to the fabric, as specified by Domain Number, have a
conflicting policy with the local switch.
Recommended
Action
Check the conflicting policy and make the new swithces and the local switch policies the same.
Severity WARNING
SEC-1317
Message <timestamp>, [SEC-1317], <sequence-number>,, INFO, <system-name>, Inconsistent
fabric, rejecting transaction.
Probable Cause Indicates that either this domain is performing FDD merge or matched domains are not the same
as what CM sees.