Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

634 Fabric OS Message Reference
53-1002448-01
SEC-1329
94
Recommended
Action
Verify the security event was planned. If the security event was planned, run the authUtil --policy
passive command to disable the Authentication Policy and retry the secModeEnable command.
Severity ERROR
SEC-1329
Message <timestamp>, [SEC-1329], <sequence-number>,, ERROR, <system-name>, IPFilter
enforcement: Failed to enforce ipfilter policy of <policy Type> type because of
<Error code>.
Probable Cause Indicates the IP filter policy enforcement failed due to internal system failure.
Recommended
Action
Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command
and contact your switch service provider.
Severity ERROR
SEC-1330
Message <timestamp>, [SEC-1330], <sequence-number>,, ERROR, <system-name>, <Name of
command> command failed - <List of databases rejecting distribution> db(s) are
coming from a non-Primary switch.
Probable Cause Indicates an attempt was made to distribute databases either from a backup fabric configuration
server (FCS) switch or from a non-FCS switch.
Recommended
Action
Verify the distribution is initiated by the primary FCS switch. Use the secPolicyShow command to
verify and correct the configuration if necessary.
Severity ERROR
SEC-1331
Message <timestamp>, [SEC-1331], <sequence-number>,, ERROR, <system-name>, Attempt to
enable secure mode failed. Reason: <Reason>.
Probable Cause Indicates the secModeEnable command failed on the fabric because default IP Filter policies are
not active on the switch, or an active transaction exists on IP Filter policies.
Recommended
Action
Verify the security event was planned. If the security event was planned, run the ipfilter --activate
default_ipv4 or the ipfilter --activate default_ipv6 command to activate default IP Filter Policies.
Use the ipfilter --save or the ipfilter --transabort commands to save or abort any active
transaction on IP Filter policies. Then retry the secModeEnable command.
Severity ERROR