Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

646 Fabric OS Message Reference
53-1002448-01
SNMP-1004
96
SNMP-1004
Message <timestamp>, [SNMP-1004], <sequence-number>, FFDC, ERROR, <system-name>,
Incorrect SNMP configuration.
Probable Cause Indicates that the SNMP configuration is incorrect and therefore the SNMP service will not work
correctly.
Recommended
Action
Change the SNMP configuration to default using the snmpConfig
--default command.
Severity ERROR
SNMP-1005
Message <timestamp>, [SNMP-1005], <sequence-number>,, INFO, <system-name>, SNMP
configuration attribute, <Changed attribute>, has changed from <Old Value> to <New
Value>.
Probable Cause Indicates that SNMP configuration has changed. The modified parameter and the old and new
parameter values are displayed in the message.
Recommended
Action
Execute the snmpConfig
--show command to view the new SNMP configuration.
Severity INFO
SNMP-1006
Message <timestamp>, [SNMP-1006], <sequence-number>,, INFO, <system-name>, <SNMP
Configuration group> configuration was reset to default.
Probable Cause Indicates that the specified SNMP configuration group was reset to the factory default.
Recommended
Action
Execute the snmpConfig
--show for the group to view the new SNMP configuration.
Severity INFO
SNMP-1007
Message <timestamp>, [SNMP-1007], <sequence-number>,, INFO, <system-name>, The last
fabric change happened at: <string>.
Probable Cause Indicates the last fabric change time.
Recommended
Action
Execute the fabricshow command to view the current fabric status.
Severity INFO