Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 649
53-1002448-01
Chapter
97
SPC System Messages
SPC-1001
Message <timestamp>, [SPC-1001], <sequence-number>,, INFO, <system-name>, S<slot number
containing Encryption Engine>, Cryptographic operation enabled.
Probable Cause Indicates the cryptographic operation is enabled on an encryption engine.
Recommended
Action
No action is required.
Severity INFO
SPC-1002
Message <timestamp>, [SPC-1002], <sequence-number>,, INFO, <system-name>, S<slot number
containing Encryption Engine>, Cryptographic operation disabled.
Probable Cause Indicates the cryptographic operation is disabled on an encryption engine.
Recommended
Action
No action is required.
Severity INFO
SPC-1003
Message <timestamp>, [SPC-1003], <sequence-number>,, ERROR, <system-name>, S<slot number
containing Encryption Engine>, Security Processor faulted.
Probable Cause Indicates the security processor is faulted because of an internal error. Cryptographic operations
are affected.
Recommended
Action
To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastboot command on the switch.
Severity ERROR