Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

652 Fabric OS Message Reference
53-1002448-01
SPC-2009
97
Recommended
Action
No action is required.
Severity INFO
SPC-2009
Message <timestamp>, [SPC-2009], <sequence-number>,, CRITICAL, <system-name>, S<slot
number containing Encryption Engine>, <module name>: Tamper event: User
zeroization.
Probable Cause Indicates the Tamper event triggered due to a user zeroize request. The Encryption Engine (EE) is
zeroized.
Recommended
Action
Execute the cryptocfg
--initEE and cryptocfg --regEE commands.
Severity CRITICAL
SPC-2010
Message <timestamp>, [SPC-2010], <sequence-number>,, CRITICAL, <system-name>, S<slot
number containing Encryption Engine>, <module name>: Crypto subsystem cover is
open.
Probable Cause Indicates the Crypto subsystem cover is open.
Recommended
Action
Close the crypto subsystem cover properly.
Severity CRITICAL
SPC-2011
Message <timestamp>, [SPC-2011], <sequence-number>,, INFO, <system-name>, S<slot number
containing Encryption Engine>, <module name>: OB1 crypto BIST success.
Probable Cause Indicates the FPGA built-in self test (BIST) was successful.
Recommended
Action
No action is required.
Severity INFO