Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 653
53-1002448-01
SPC-2012
97
SPC-2012
Message <timestamp>, [SPC-2012], <sequence-number>,, INFO, <system-name>, S<slot number
containing Encryption Engine>, <module name>: User zeroization command completed
successfully. Tamper INT status <Status>.
Probable Cause Indicates the User zeroization command has completed successfully. The Encryption Engine (EE) is
zeroized.
Recommended
Action
Execute the cryptocfg
--initEE and cryptocfg --regEE commands.
Severity INFO
SPC-2013
Message <timestamp>, [SPC-2013], <sequence-number>,, WARNING, <system-name>, S<slot
number containing Encryption Engine>, <module name>: Oscillator Failure Detected.
Probable Cause Indicates hardware failure.
Recommended
Action
Shelf life of the system may be reduced. Contact the vendor for further instructions.
Severity WARNING
SPC-2014
Message <timestamp>, [SPC-2014], <sequence-number>,, WARNING, <system-name>, S<slot
number containing Encryption Engine>, <module name>: Low Battery Level Detected.
Probable Cause Indicates that the battery is depleted.
Recommended
Action
System operation will be unaffected while facility power is present. Schedule replacement with the
vendor.
Severity WARNING
SPC-2040
Message <timestamp>, [SPC-2040], <sequence-number>,, ERROR, <system-name>, S<slot number
containing Encryption Engine>, <module name>: SPD Device minornum <MinorNum> is
already open. state <State>.
Probable Cause Indicates that the Security Policy Database (SPD) device has already opened or is busy either for
sysctrld or keyappd.