Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

658 Fabric OS Message Reference
53-1002448-01
SPC-3010
97
SPC-3010
Message <timestamp>, [SPC-3010], <sequence-number>,, WARNING, <system-name>, S<slot
number containing Encryption Engine>, <module name>: SEK integrity failure during
initialization.
Probable Cause Indicates the Crypto Module internal Secret Encryption Key has been corrupted or has not been
initialized.
Recommended
Action
Execute the cryptocfg
--initEE and cryptocfg --regEE commands.
Severity WARNING
SPC-3011
Message <timestamp>, [SPC-3011], <sequence-number>,, ERROR, <system-name>, S<slot number
containing Encryption Engine>, <module name>: Persistent data storage error: <SP
status code>, KEK: <KEK octet 1> <KEK octet 2> <KEK octet 3> <KEK octet 4>.
Probable Cause Indicates an attempt to store Crypto Module internal data using the Secret Encryption Key failed -
most likely, the EE has been zeroized or tampered with.
Recommended
Action
Execute the cryptocfg
--initEE and cryptocfg --regEE commands, then recover or restore the
needed primary and secondary KEKs.
Severity ERROR
SPC-3012
Message <timestamp>, [SPC-3012], <sequence-number>,, ERROR, <system-name>, S<slot number
containing Encryption Engine>, <module name>: Persistent data retrieval error: <SP
status code>.
Probable Cause Indicates an attempt to read Crypto Module internal data using the Secret Encryption Key failed -
most likely, the EE has been zeroized or tampered with.
Recommended
Action
Execute the cryptocfg
--initEE and cryptocfg --regEE commands, then recover or restore the
needed primary and secondary KEKs.
Severity ERROR
SPC-3013
Message <timestamp>, [SPC-3013], <sequence-number>,, ERROR, <system-name>, S<slot number
containing Encryption Engine>, <module name>: SEK generation failure: <SP status
code>.
Probable Cause Indicates the Crypto Module internal Secret Encryption Key could not be generated.