Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 675
53-1002448-01
SS-1007
99
Recommended
Action
Restart the switch using the reboot command and then execute the supportSave command.
Severity WARNING
SS-1007
Message <timestamp>, [SS-1007], <sequence-number>,, WARNING, <system-name>, supportsave
failed for the slot <Slot Number>. Reason: No response from the blade in the
specified slot for the given supportsave request.
Probable Cause Indicates that there was no reponse from the blade in the specified slot for the given supportsave
request.
Recommended
Action
Restart the switch using the reboot command and then execute the supportSave command.
Severity WARNING
SS-1008
Message <timestamp>, [SS-1008], <sequence-number>,, WARNING, <system-name>, supportsave
failed for the slot <Slot Number>. Reason: BP supportsave timeout.
Probable Cause Indicates that the specified slot has taken more time than expected to collect the supportsave logs.
Recommended
Action
Execute the supportSave command again.
Severity WARNING
SS-1009
Message <timestamp>, [SS-1009], <sequence-number>,, WARNING, <system-name>, <slot number
and its node name(BP/DP)> supportsave failed. Reason:No ISC connection for <slot
number and its node name(BP/DP)>.
Probable Cause Indicates that there is no Inter-Subsystem Communication (ISC) connection for the specified node
slot.
Recommended
Action
Restart the switch using the reboot command and then execute the supportSave command.
Severity WARNING