Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 679
53-1002448-01
SSMD-1008
100
Recommended
Action
Try again after sometime. If the problem persists, execute the supportSave command and then
restart or power cycle the switch.
Severity ERROR
SSMD-1008
Message <timestamp>, [SSMD-1008], <sequence-number>,, ERROR, <system-name>, Apptype TCAM
Table full for Slot:<slot number> chip:<Chip number in the slot>.
Probable Cause Indicates that the application type TCAM table is full on the specified chip.
Recommended
Action
Remove the unused protocol-based VLAN classifiers and Layer 2 Extended access control lists
(ACLs).
Severity ERROR
SSMD-1200
Message <timestamp>, [SSMD-1200], <sequence-number>,, WARNING, <system-name>, QoS failed
programming ASIC <ASIC slot number>/<ASIC chip number> Multicast Rate Limit.
Probable Cause Indicates that DCE SSM encountered an unexpected error in programming the dataplane
application-specific integrated circuit (ASIC) for the enforcing Multicast Rate Limit feature.
Recommended
Action
Delete and reapply Quality of Service (QoS) Multicast Rate Limit policy using the qos rcv-queue
multicast rate-limit command.
If the problem persists, restart or power cycle the switch.
Severity WARNING
SSMD-1201
Message <timestamp>, [SSMD-1201], <sequence-number>,, WARNING, <system-name>, QoS failed
programming ASIC <ASIC slot number>/<ASIC chip number> Multicast Tail Drop.
Probable Cause Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
the enforcing Multicast Tail Drop feature.
Recommended
Action
Delete and reapply QoS Multicast Tail Drop policy using the qos rcv-queue multicast threshold
command.
If the problem persists, restart or power cycle the switch.
Severity WARNING