Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

696 Fabric OS Message Reference
53-1002448-01
SULB-1009
101
Table 8 lists additional firmwareDownload error messages and error codes. They provide more
details on why firmwareDownload failed.
"Switch is relocating the AP image." 0xa9
"The AP image is relocated successfully." 0xaa
"Switch reboots during relocating the AP image. The operation will be restarted." 0xab
“Blade failed to reboot with the original image. firmwareRestore command failed.” 0xac
TABLE 8 Error messages and error codes
Error message Error code
"Image is up-to-date. No need to download the same version of firmware." 0xF
“Upgrade is inconsistent. Run the bootEnv (root) command to correct the inconsistency before
proceeding.”
0x10
“OSRootPartition is inconsistent. Run the bootEnv (root) command to correct the inconsistency
before proceeding. For example: swap OSRootPartitions and reboot.”
0x11
“Unable to access the required package list file. Check whether the switch is supported by the
requested firmware. Also check firmwareDownload help page for other possible failure
reasons.”
0x12
"The RPM package database is inconsistent. Contact your service provider for recovery." 0x13
"Out of memory." 0x14
"Failed to download RPM package." 0x15
"Unable to create firmware version file." 0x16
"Unexpected system error." 0x17
“Error in getting lock device for firmwareDownload.” 0x18
“Error in releasing lock device for firmwareDownload.” 0x19
firmwareCommit failed.” 0x1a
"Firmware directory structure is not compatible. Check whether the firmware is supported on
this platform."
0x1b
"Failed to load the Linux kernel image." 0x1c
“OSLoader is inconsistent. Run the bootEnv (root) command to correct the inconsistency before
proceeding.”
0x1d
“New image has not been committed. Run firmwareCommit or firmwareRestore first and then
try firmwareDownload.”
0x1e
firmwareRestore failed.” 0x1f
"Both images are mounted to the same device." 0x20
“Unable to unionist old packages.” 0x21
firmwareDownload is already in progress.” 0x22
firmwareDownload timed out.” 0x23
"Our of disk space." 0x24
TABLE 7 Status messages and status codes (Continued)
Status message Status code