Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 699
53-1002448-01
SULB-1010
101
In a director-class switch, when firmwareDownload fails, the two CPs may end up with different
versions of firmware and they may not gain high-availability (HA) sync. In that case, run
firmwareDownload single mode (-s) to upgrade the firmware on the standby CP to the same version
as the active CP. Then retry firmwareDownload to download the desired version of firmware onto
the CPs.
Refer to the Fabric OS Administrator’s Guide for troubleshooting information.
Severity INFO
SULB-1010
Message <timestamp>, [SULB-1010], <sequence-number>, INFO, <system-name>, Firmwarecommit
failed (status=0x<error code>).
Probable Cause Indicates the firmwareCommit command has failed. The error code provides debugging
information. See Table 8 for more information.
Recommended
Action
If the failure is caused by an inconsistent filesystem, contact your switch service provider.
Severity INFO
SULB-1011
Message <timestamp>, [SULB-1011], <sequence-number>,, INFO, <system-name>,
Firmwaredownload command failed. <error string>.
Probable Cause Indicates the firmwareDownload command has failed. The additional state code indicates where in
the process it failed. Status code provides debugging information (see the tables in message
1009).
Recommended
Action
Run the firmwareDownloadStatus command for more information.
Refer to the Troubleshooting section of the Fabric OS Administrator's Guide for additional
information.
Severity INFO
SULB-1017
Message <timestamp>, [SULB-1017], <sequence-number>, ERROR, <system-name>,
Firmwaredownload failed in slot <Slot number>.
Probable Cause Indicates the firmwareDownload command has failed in the specified blade. The error may be
caused by an inconsistent AP blade firmware stored on the active CP. It may also be caused by an
internal Ethernet issue or by a persistent storage hardware failure.