Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 703
53-1002448-01
SULB-1032
101
Recommended
Action
Wait for the operation to complete.
Severity WARNING
SULB-1032
Message <timestamp>, [SULB-1032], <sequence-number>, WARNING, <system-name>, Relocating
an internal firmware image on the CP.
Probable Cause Indicates the switch has started a firmware download to the co-CPU.
Recommended
Action
Wait for the operation to complete.
Severity WARNING
SULB-1033
Message <timestamp>, [SULB-1033], <sequence-number>, WARNING, <system-name>, Switch has
completed relocating the internal firmware image.
Probable Cause Indicates the firmwareDownload process has completed normally on the switch.
Recommended
Action
Run the firmwareShow command to verify the firmware versions. Run the switchShow command to
make sure the switch is enabled.
Severity WARNING
SULB-1034
Message <timestamp>, [SULB-1034], <sequence-number>, ERROR, <system-name>, Relocation of
internal image timed out.
Probable Cause Indicates there may be an error caused by the switch initialization issue after the internal image is
relocated. It may also be caused by the internal Ethernet issue or by persistent storage failure.
Recommended
Action
Restart the switch. This will cause the internal image to be relocated again. Use the
firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your
switch service provider.
Severity ERROR
SULB-1035
Message <timestamp>, [SULB-1035], <sequence-number>, ERROR, <system-name>, An error has
occurred during relocation of the internal image.