Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

708 Fabric OS Message Reference
53-1002448-01
SWCH-1004
102
SWCH-1004
Message <timestamp>, [SWCH-1004], <sequence-number>,, ERROR, <system-name>, Blade attach
failed during recovery, disabling slot = <slot number>
.
Probable Cause Indicates a blade has failed during failover or recovery.
Recommended
Action
On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn
command.
On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000,
7500, or AP7600 switch, reboot or power cycle the switch
Severity ERROR
SWCH-1005
Message <timestamp>, [SWCH-1005], <sequence-number>,, ERROR, <system-name>, Diag attach
failed during recovery, disabling slot = <slot number>
.
Probable Cause Indicates the Diag blade attach has failed during failover or recovery.
Recommended
Action
On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn
command.
On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000,
7500, or AP7600 switch, reboot or power cycle the switch.
Severity ERROR
SWCH-1006
Message <timestamp>, [SWCH-1006], <sequence-number>,, WARNING, <system-name>, HA state
out of sync: Standby CP (ver = <standby SWC version>) does not support NPIV
functionality. (active ver = <active SWC version>, NPIV devices = <'1' if NPIV
devices exist; Otherwise '0'>).
Probable Cause Indicates the standby control processor (CP) does not support N_Port ID Virtualization (NPIV)
functionality, but the switch has some NPIV devices logged into the fabric.
Recommended
Action
Load a firmware version on standby that supports NPIV functionality, using the firmwareDownload
command.
Severity WARNING
SWCH-1007
Message <timestamp>, [SWCH-1007], <sequence-number>,, WARNING, <system-name>, Switch port
<port number> disabled due to \"<disable reason>\".
Probable Cause Indicates the switch port is disabled due to the reason displayed in the message.