Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 709
53-1002448-01
SWCH-1008
102
Recommended
Action
Based on the disable reason displayed, proper corrective action may to be required to restore the
port.
If the disable reason is due to insufficient frame buffers, reduce the distance or speed settings for
the port to reduce the buffer requirement of the link. Alternatively, one or more ports in the port
group must be disabled to make more buffers available for the link.
Refer to the Fabric OS Administrator’s Guide for more information about buffers.
Severity WARNING
SWCH-1008
Message <timestamp>, [SWCH-1008], <sequence-number>,, WARNING, <system-name>, <area
string> are port swapped on ports that do not support port swap. Slot <slot
number> will be faulted.
Probable Cause Indicates the blade is enabled with the port configuration that does not support port swap.
Recommended
Action
Replace the blade with ports that support port swap. Then swap the ports back to the ports default
area.
Refer to the Fabric OS Administrator’s Guide for more information on port swapping.
Severity WARNING
SWCH-1009
Message <timestamp>, [SWCH-1009], <sequence-number>,, WARNING, <system-name>, Shared area
having Trunk Area (TA) enabled on slot <slot number>. Shared areas that have TA
enabled will be persistenly disabled.
Probable Cause Indicates the blade is enabled with a port configuration that had Trunk Area previously enabled on
a shared area port.
Recommended
Action
You must disable Trunk Area on ports that had Trunk Area enabled previously.
Refer to the Fabric OS Administrator’s Guide for more information.
Severity WARNING
SWCH-1010
Message <timestamp>, [SWCH-1010], <sequence-number>,, WARNING, <system-name>, Trunk Area
(TA) enabled on slot <slot number> with switch not in PID format 1. TA enabled
ports will be persistently disabled.
Probable Cause Indicates the blade is enabled with the port configuration that had Trunk Area enabled previously.
Recommended
Action
You must disable Trunk Area on ports that had Trunk Area enabled previously.