Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

716 Fabric OS Message Reference
53-1002448-01
SYSC-1004
103
It could also indicate that the current option number could not be read from the chassis option
storage device (the world wide name (WWN) card).
This message occurs only on the Brocade 24000 and 48000.
Recommended
Action
As indicated in the message, run the chassisConfig command to change to one that is valid on this
platform running this firmware. Note that the chassisConfig option 1 should be valid for all
platforms running any valid firmware.
Severity CRITICAL
SYSC-1004
Message <timestamp>, [SYSC-1004], <sequence-number>,, INFO, <system-name>, Daemon <Daemon
name to restart> restart successful.
Probable Cause Indicates that a terminated daemon is being restarted by the system automatically.
Recommended
Action
Use the supportSave command to gather troubleshooting data.
Severity INFO
SYSC-1005
Message <timestamp>, [SYSC-1005], <sequence-number>,, WARNING, <system-name>, Daemon
<Daemon name to restart> is not restarted (Reason: <Restart failure reason>)
Probable Cause Indicates a terminated daemon has not restarted, either a restart limit has been reached or a
restart action has failed.
Recommended
Action
Use the supportSave command to gather troubleshooting data. Issue a reboot or haFailover
command to recover the system and limit the traffic disruption.
Severity WARNING