Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 717
53-1002448-01
Chapter
104
SYSM System Messages
SYSM-1001
Message <timestamp>, [SYSM-1001], <sequence-number>, FFDC, CRITICAL, <system-name>, No
memory.
Probable Cause Indicates the switch has run out of system memory.
Recommended
Action
Run the memShow command to view the switch memory usage.
Restart or power cycle the switch.
Run the supportFtp command to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity CRITICAL
SYSM-1002
Message <timestamp>, [SYSM-1002], <sequence-number>,, INFO, <system-name>, <number>,
Switch: <Switch number>
Probable Cause Indicates a user has executed either the switchShutdown or switchReboot command. All services
are brought down for a logical switch.
Recommended
Action
No action is required if the switchShutdown or switchReboot command was executed intentionally.
If the switchShutdown command was run, you must run the switchStart command to restart traffic
on the logical switch.
Severity INFO
SYSM-1003
Message <timestamp>, [SYSM-1003], <sequence-number>,, INFO, <system-name>, <number>,
Switch: <start reason>
Probable Cause Indicates the user executed the switchStart or switchReboot command. This indicates that all
services are brought back up after a temporary shutdown of that logical switch.
Recommended
Action
No action is required if the switchStart command was executed intentionally. Because reinitializing
a switch is a disruptive operation and can stop I/O traffic, you might have to stop and restart the
traffic during this process.
Severity INFO