Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

718 Fabric OS Message Reference
53-1002448-01
SYSM-1004
104
SYSM-1004
Message <timestamp>, [SYSM-1004], <sequence-number>,, ERROR, <system-name>, Failed to
retrieve current chassis configuration option, ret=<Unknown>
Probable Cause Indicates there was a failure to read configuration data from the WWN card.
Recommended
Action
Verify that the world wide name (WWN) card is present and operational and that the affected
control processor (CP) is properly seated in its slot.
Severity ERROR
SYSM-1005
Message <timestamp>, [SYSM-1005], <sequence-number>, FFDC, CRITICAL, <system-name>, CP
blade in slot <Slot number> failed to retrieve current chassis type.
Probable Cause Indicates there was a failure to read the chassis type from the system.
Recommended
Action
Verify the control processor (CP) blade is operational and is properly seated in its slot.
Severity CRITICAL
SYSM-1006
Message <timestamp>, [SYSM-1006], <sequence-number>, FFDC, CRITICAL, <system-name>, CP
blade in slot <Slot number> is incompatible with the chassis type.
Probable Cause Indicates this chassis type is not compatible with the control processor (CP) blade.
Recommended
Action
Use the CP blade on a compatible chassis.
Severity CRITICAL
SYSM-1007
Message <timestamp>, [SYSM-1007], <sequence-number>,, WARNING, <system-name>, PERMITTING
USE OF INCOMPATIBLE CHASSIS FOR CP IN SLOT <Slot number>. DATA ERRORS MAY RESULT.
Probable Cause Indicates overriding the incompatible control processor (CP)/chassis check.
Recommended
Action
Delete the /var/chassis_backplane_override file and restart the CP.
Severity WARNING