Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 749
53-1002448-01
Chapter
114
ZEUS System Messages
ZEUS-1001
Message <timestamp>, [ZEUS-1001], <sequence-number>,, ERROR, <system-name>, Port <port
number> port fault. Please change the SFP or check cable.
Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty
cable between peer ports.
Recommended
Action
Verify if you are using a compatible SFPs on the peer ports. Determine whether the SFPs have
deteriorated and the Fibre Channel cable is faulty. Replace the SFPs or cable if necessary.
Severity ERROR
ZEUS-1002
Message <timestamp>, [ZEUS-1002], <sequence-number>, FFDC, ERROR, <system-name>, Port
<port number> chip faulted due to internal error.
Probable Cause Indicates an internal error. All the ports on the blade or switch will be disruptive.
Recommended
Action
For a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade to recover
the system. For a non-bladed system, perform fastBoot command on the switch to recover the
system.
Severity ERROR
ZEUS-1003
Message <timestamp>, [ZEUS-1003], <sequence-number>, , CRITICAL, <system-name>, S<slot
number>,C<chip index>: HW ASIC Chip error type = 0x<chip error type>.
Probable Cause Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may
degrade data traffic.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the blade.
Severity CRITICAL