Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 755
53-1002448-01
ZONE-1008
115
Recommended
Action
The following are the ways to avoid this problem:
Avoid having too many hosts zoned with a set of target devices at a single port.
Avoid having too many zones directed at a single port group on the switch.
Severity INFO
ZONE-1008
Message <timestamp>, [ZONE-1008], <sequence-number>,, WARNING, <system-name>, Port <port
number> out of CAM entries.
Probable Cause Indicates that the total number of entries of S_ID CAM is above the limit while creating or adding a
zone group. The maximum number of CAM entries allowed depends on the application-specific
integrated circuit (ASIC).
Recommended
Action
If hardware zoning enforcement is preferred, edit the zoning database to have zoned port IDs
(PIDs) for that port.
Severity WARNING
ZONE-1010
Message <timestamp>, [ZONE-1010], <sequence-number>,, WARNING, <system-name>, WARNING -
Duplicate entries in zone (<zone name>) specification.
Probable Cause Indicates that there are duplicate entries in the specified zone object. This message occurs only
when enabling a zone configuration.
Recommended
Action
Check the members of the zone using the using the cfgShow command. Delete the duplicate
member using the using the zoneRemove command.
Severity WARNING
ZONE-1012
Message <timestamp>, [ZONE-1012], <sequence-number>,, WARNING, <system-name>, All ports
are offline.
Probable Cause Indicates that all the ports in a zone are offline.
Recommended
Action
Check the device connetion.
Severity WARNING