Brocade Fabric OS Message Reference - Supporting Fabric OS v7.0.1 (53-1002448-01, March 2012)

Fabric OS Message Reference 869
53-1002448-01
Chapter
139
AUDIT UCST System Messages
UCST-1021
Message <Sequence Number> AUDIT, <timestamp>, [UCST-1021], INFO, CFG,
<event-initiator-details>, <event-location>, , In-order delivery option has been
enabled.
Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery
of frames during topology changes.
Recommended
Action
No action is required.
Severity INFO
UCST-1022
Message <Sequence Number> AUDIT, <timestamp>, [UCST-1022], INFO, CFG,
<event-initiator-details>, <event-location>, , In-order delivery option has been
disabled.
Probable Cause Indicates the IOD option has been disabled for the switch. This may cause out-of-order delivery of
frames.
Recommended
Action
No action is required.
Severity INFO
UCST-1023
Message <Sequence Number> AUDIT, <timestamp>, [UCST-1023], INFO, CFG,
<event-initiator-details>, <event-location>, , Dynamic Load Sharing option has
been enabled.
Probable Cause Indicates the DLS option has been enabled for the switch. This will move existing routes to a new
redundant path, when this path becomes available.
Recommended
Action
No action is required.
Severity INFO