HP B-series Network Advisor Enterprise, Professional Plus, and Professional 11.1.5 Release Notes (5697-2464, January 2013)

Table 8 HP Network Advisor 11.1.1 closed defects (continued)
SolutionClosed fixes summary
Fixed in HP Network Advisor 11.1.1A boot image update fails with an error message for windows and VMware
ESX hosts.
Fixed in HP Network Advisor 11.1.1Installation hangs at ‘Initialize Database' when a non-default database port
number is provided in the Server Configuration page of the Configuration
Wizard.
Fixed in HP Network Advisor 11.1.1The Help dialog is not getting launched in the driver repository dialog.
Fixed in HP Network Advisor 11.1.1Previous settings in the LUN selection screen are not active when adding a
new LUN path, and users are required to re-apply the LUN setting in the '
LUN view' dialog.
Fixed in HP Network Advisor 11.1.1Duplicate ESX host entries are shown in the Product Tree for all the
discovered vCenters after the fabric connected to the ESX host is unmonitored
and monitored.
Fixed in HP Network Advisor 11.1.1In a FICON environment, the merge Operation fails with the error message
Internal error occurred - Failed to perform the
requested cascaded FICON merge configurations.
Fixed in HP Network Advisor 11.1.1Deleting a vCenter fails when the fabric is unmonitored, but a host is still
being managed by the vCenter.
Fixed in HP Network Advisor 11.1.1Changing Top Talkers from Tx to Rx fails with an error.
Fixed in HP Network Advisor 11.1.1Setting SCC policy fails due to the inability to establish connection to the
switch.
Fixed in HP Network Advisor 11.1.1In the LSAN zoning dialog, the Alias name is not shown in the WWN-fabric
assigned potential member panel.
Fixed in HP Network Advisor 11.1.1Ping or traceroute fail when IP interfaces and crossport interfaces are defined
on XGE ports.
Fixed in HP Network Advisor 11.1.1A duplicate entry is displayed for each device in the Configuration
Repository after migrating from Network Advisor 11.1.0 to Network Advisor
11.1.1.
Workaround prior to upgrade: Use
support save collection without SSL mode
or use standalone HCM with SSL mode.
Support save collection for HBA/CNA fails when SSL is enabled.
Fixed in HP Network Advisor 11.1.1.
Fixed in HP Network Advisor 11.1.1All raslog based messages trigger event actions for SNMP Traps and
Syslogs.
Workaround prior to upgrade: Provide
the IP address in the ‘Provide IP address,
WWN, source name text’ box.
Unable to create event action while selecting a switch with E_Port trunks
configured on it.
Fixed in HP Network Advisor 11.1.1.
Fixed in HP Network Advisor 11.1.1Incorrect details are displayed for the link failure event in the Master Log
event description.
Fixed in HP Network Advisor 11.1.1The Unbind port addresses operation fails when ports are moved between
logical switches.
Workaround prior to upgrade: Use CLI to
import and register the LKM certificate.
If the LKM certificate has a value other than ‘Decru the encryption switch
will not accept the certificate.
Fixed in HP Network Advisor 11.1.1.
Fixed in HP Network Advisor 11.1.1Logs may become flooded by SNMPUSM messages.
Fixed in HP Network Advisor 11.1.1Invalid characters (series of numbers like an OID) are erroneously displayed
in the Description of the Master Log Event.
Migration and upgrades 21