HP StorageWorks Fabric OS 5.3.1 release notes (AA-RWEYI-TE, March 2008)

Closed defect summary
Solution
New active CP got Oops and reboot during initialization after
hafailover command issued.
Fixed in Fabric OS 5.3.0
After CP reboot, VE tunnel doesn’t come up due to GE0 port on
FR4-18i stuck in No _Sync state when using copper SFP’s.
Fixed in Fabric OS 5.3.0
Switch doesn’t generate RSCN following zoning changes using
cfgEnable in interop m ode, resulting in no PLOGI from hosts, and
no target discovery.
Fixed in Fabric OS 5.3.0
When more than
the supported number of Ex_Ports attached to same
edge fabric wi
th FCR switches, switch m ay panic causing continuous
rebooting.
Fixed in Fabric OS 5.3.0
When more than the supported number of intelligent blades (FR4-18i,
FC4-16IP, etc) conguredin4/256,poweringupthe4thand5th
blades at the same time results in a failover.
Fixed in Fabric OS 5.3.0
In rare occurrence, FR4-18i Blade could become faulty after rmware
download and slotpoweron followed by slotpoweroff.
Fixed in Fabric OS 5.3.0
Tape backup
job failures occasionally observed in congested IO
conditions
due to tape pipelining not properly handling target
recovery.
Fixed in Fabric OS 5.3.0
After changing F ID & enabling F CR switch, all connected/active
ports remain disabled.
Fixed in Fabric OS 5.3.0
If active CP fails over after FC4-16ip por t Blade runs slotpower on,
all the FC4-16ip iSCSI ports can get stuck at “No_Sync” while FC
ports come online.
Fixed in Fabric OS 5.3.0
After an a
ll switches disable on 4/256 with FC4-48 port blades,
standby C
P asserted and rebooted.
Fixed in Fabric OS 5.3.0
HAfailover during FCIP IO through IPSec enabled tunnel
sometimes causes VE port to go down, then come back up.
Fixed in Fabric OS 5.3.0
User was able to congure isns client via isnsccfg to communicate
with isns server through a port on FR4-18i, but this will not work (nor
should it).
Fixed in Fabric OS 5.3.0
FICON tr
aps sent with wrong “Enterprise value resulting in trap
being p
rocessed as a swFault.
Fixed in Fabric OS 5.3.0
In Web Tools customized port detail report, the report will b e
generated for all ports even if the user gives a particular p ort range
as a lter.
Fixed in Fabric OS 5.3.0
On 2Gb/s platforms, switch panic can occur if unstable or faulty port
generates excessive number of interrupts.
Fixed in Fabric OS 5.3.0
When r
ebooting the active CP from Root, the warning text that is
displayed when rebooting from Admin to warn that rebooting the
acti
ve CP will disrupt trafc, is not displayed.
Fixed in Fabric OS 5.3.0
In edge to backbone fabric conguration with target in backbone
fabric and host in edge fabric, 400 MP Router neither accepted or
aborted a PLO GI. Only happens when there are devices in the fabric
for which the link is taken online/ofine quickly within a short period
of time.
Fixed in Fabric OS 5.3.0
4/64 SAN switch with 5.1.0d experienced HW/SW interlock that
became stuck requiring port disable/enable to clear the condition.
This issue was not reproducible.
Fixed in Fabric OS 5.3.0
Us
ing API to access default zoning information could cause switch
to
panic due to invalid pointer.
Fixed in Fabric OS 5.3.0
18