Closed defect summary
Solution
WebToolsismiss
ing “Invalid CRCS” under Fabr ic Watch end to end
class pull down
menu, due to missing “CRC Error option.
Fixed in Fabric OS 5.3.0
GUI component size squeezed due to lack of proper refresh after
resizing.
Fixed in Fabric OS 5.3.0
Errlog (raslog) messages not available for diagnosing DHCP
problems.
Fixed in Fabric OS 5.3.0
Web Tools allows (switch,port) members to be added as member of a
zone in interop mode, but this won’t actually be created successfully.
Fixed in Fabric OS 5.3.0 by blocking
addition of D
,P members & D,P
zoning when i
n interop mode.
Some switches are segmented with reason alias ID overlap when
selected switches in fabric congured to use Alias Server due to lack
of Alias Server support in Fabric OS 5.2.0.
Fixed in Fabric OS 5.3.0
On Solaris, when switch already in marginal state and another
marginal event occurs, Events list in Call Home email not getting
updated with exact reason for the alert.
Fixed in Fabric OS 5.3.0
FCIP error message not correct while editing/adding the subnet mask
of an IP ad
dress that conicts with the existing IP addresses.
Fixed in F
abric OS 5.3.0
EZManager doesn’t differentiate ports as storage and hosts if no
devices/hosts connections made.
Fixed in Fabric OS 5.3.0
During stress testing with large number of sent error frames leading to
generation of very big core le, and watchdog timer timeout.
Fixed in Fabric OS 5.3.0
Enc out c
ounter increases on unused ports on 2Gb platforms after
HAreboo
torrmware download.
Fixed in Fabric OS 5.3.0
Web Tools is not displaying “logged in” Radius account information.
Fixed in Fabric OS 5.3.0
Units for temperature, Rx and Tx power are not shown on SFP tab
in Web Tools.
Fixed in Fabric OS 5.3.0
Web Tool
sdoesntdisplayunitsofTotal Bandwidth and Bandwidth
Demand
in Fabric T opology Window.
Fixed in Fabric OS 5.3.0
Web Tools incorrectly returns Directory change failed error
message rather than le path provided is not valid” error message
when config upload fails due to invalid le path.
Fixed in Fabric OS 5.3.0
Modifying port speed and trunking on FC4-48 ports from Web Tools,
followed by HAfailover, and then trying to re-launch, Port Admin
window on those same ports fails to reload Web Tools window.
Fixed in Fabric OS 5.3.0
F_Port route cleanup doesn’t happen correctly when NPIV is used on
switch in Access Gateway mode.
Fixe
d in Fabric OS 5.3.0
EZSwitch Setup device display is overlapped in Display Connection
window when window size not maximized.
Fixed in Fabric OS 5.3.0
Portstatsclear help page description of behavior on 2Gb and
4Gb platforms is ambiguous.
Fixed in Fabric OS 5.3.0
FR4-18i tracedump les contain many BP error messages and one
emp
ty le, p otentially leading to incomplete support les.
Fix
ed in Fabric OS 5.3.0
During stress testing when rebooting all core switches in a loop,
E-ports may get stuck in “Mod_Val” mode.
Fixed in Fabric OS 5.3.0
Error messages are generated when applying iSCSI easycreate
operationfromWebToolsonunreachableFCTargets. Noerror
messages if LUN information is not retrievable from an FC Target.
Errors are only displayed when applying the operation.
Fixed in Fabric OS 5.3.0
20