HP StorageWorks Fabric OS 5.3.1 release notes (AA-RWEYI-TE, March 2008)

Closed defect summary
Solution
SNMPtrapsrepeatedlysentfromtheswitchevery2secondswhen
port taken out of a fault state implicitly by removing cable or module.
Caused by too ma
ny port ofine SCNs b eing sent out during port
fault and recover when there is laser fault.
Fixed in Fabric OS 5.3.0
Firmware downgrade to Fabric OS 5 .1 or earlier is blocked even
after ports 256 384 are removed from DCC policy created using
[*] option. Currently have to delete DCC policy to avoid this.
Fixed in Fabric OS 5.3.0
Admin user account with permissions to only Admin Domain 255
can create Admin Domains, but only Admin user accounts with
permissions for all Admin Domains should be able to do this.
Fixed in Fabric OS 5.3.0
Conrmatio
n dialog doesn’t appear when name server table closed
by clicking
the “X” button. User experiences unexpected close when
clicking
X” button.
Fixed in Fabric OS 5.3.0
Detailed view of any device doesn’t refresh p roperly when Auto
refresh option is selected & user resizes/scrolls the window.
Fixed in Fabric OS 5.3.0
Role name, and sometimes user name, missing from error message
when user exits from a Telnet session.
Fixed in Fabric OS 5.3.0
The 2 /16v switch produces ARB(vc) ll words instead of idles which
could cause failures with certain long distance devices when running
Fabric OS
5.2 with the following port conguration:
nl
portcfglongdistance <port> LS 1 50
nl
portcfgislmode <port> 1
Fixed in Fabric OS 5.3.0
Web Tools not c orrectly reecting physical switch state of a
persistently disabled switch when the switch is fastbooted. LEDs are
shown unlit instead of slowly blinking yellow.
Fixed in Fabric OS 5.3.0
No event
is generated when the IP address of a switch is changed,
so user can’t determine IP address of the switch was changed by
issuing the command errdump or errshow because IP address
change event was not registered.
Fixed in Fabric OS 5.3.0
Several issues observed in ZoneAdmin and in Admin Domain when
switch is congured in PID format 2, including being unable to see
ports 1 6-32.
Fixed in Fabric OS 5.3.0
During stress testing, a signicant delay in trafccomingback
from a Fibre Channel Router (FCR) failure in fully redundant SAN
conguration was seen, as trafc temporarily stopped before taking
redundant path after rebooting one of the FCRs in dual b ack bone
fabric.
Fixed in Fabric OS 5.3.0
During stress testing, switch may report fabric busy following issuance
of a
long string of operations repeatedly.
Fix
ed in Fabric OS 5.3.0
When using i nteractive mode to execute pathinfo,butwithan
invalid source port value, there is no error message.
Fixed in Fabric OS 5.3.0
After receiving login reject on FC4-16IP, subsequent login attempts
may fail intermittently under some conditions. This c an be avoided
by moving the session back to init state after rejecting a login.
Fixed in Fabric OS 5.3.0
Du
ring stress testing, FC4-16IP m ay run out of m emory if continually
running slotpoweroff/on on multip le FC4-16IP blades for long
period.
F
ixed in Fabric OS 5.3.0
In Secure FOS, Web Tools gets null pointer from java console rather
than the m odify dialog to modify description and/or status when
trying to modif y default admin and user accounts.
Fixed in Fabric OS 5.3.0 which now
includes all Secure FOS functionality.
22