HP StorageWorks Fabric OS 5.3.1 release notes (AA-RWEYI-TE, March 2008)

Closed d efect summ ar y
Solution
Collecting supportsave info on 4/256 could cause error message
on active CP console log.
Fixed in Fabric OS 5.3.0
Host takes a long time to log in when disabled/unused GE-iSCSI
ports have IP addresses congured to them. When host does a
"SendTargets=All" those IP addresses will be in the list, but will be
unreachable.
Fixed in Fabric OS 5.3.0
After changing Backbone FID, switchshow doesn’t display LE port
information for some EX or VEX ports. Ports function correctly, only
the display is incorrect.
Fixed in Fabric OS 5.3.0
On FC4-16IP iSCSI Blade, console log for iSNS reports the
management p
ort as slot/port 0/0.
Fixed in Fabr
ic OS 5.3. 0
With multiple FC4-16IP blades in multiple 4/256 directors in the
fabric and ISNSC enabled, iSNS error message is logged on only
oneswitch,butshouldbeloggedonallswitchesinthefabric.
Fixed in Fabric OS 5.3.0
May not see the targets after successful iSCSI login with FC4-16IP
using AIX if immediate data is enabled.
Fixed in Fabric OS 5.3.0
LE ports no
t up after trunk disable/enable as evidenced by EX_Port
not coming
online.
Fixed in Fabric OS 5.3.0
Switchshow shows EX_Port left disabled after it’s enabled due to
setting VC Credits failure. In addition, when EX_Port trunk master is
unplugged, non-trunk master ports are disabled.
Fixed in Fabric OS 5.3.0
Execquer y Brocade_SwitchFcPortRateStats is not returning
correct Instances. When Admin Domain’s are created on the switch
side without stopping the SMI-A, it always returns Instances with
respect to Admin Domain0.
Fixed in Fabric OS 5.3.0
Sometimes when trying to add/modify Admin Domai n list for mul tiple
user acc
ounts simultaneously, Admin Domain list for user accounts
change
s.
Fixed in Fabric OS 5.3.0
Port detail report shows incorrect values for iSCSI ports with FC 4 -16IP
Blade.
Fixed in Fabric OS 5.3.0
swFCPortOpStatus of swFCPortScn is not reported correctly.
Fixed in Fabric OS 5.3.0
Excess
ive logins cause out-of-memory (OOM) panic while switching
betwee
nuserrolesandexecutingConfigshow command.
Fixed in Fabric OS 5.3.0
Vulnerabilities reported about open SSL VU#386964 & VU#547300.
For VU#547300:OpenSSL SSL_get_shared_ciphers() vulnerable to
buffer overow . For VU#386964:OpenSSL SSLv2 client code fails to
properly check for NULL.
Fixed in Fabric OS 5.3.0
Denial-of-Service condition affecting X.509 certicates verication
(NISCC #729 618) due to SSL vulnerability in OpenSSL. FOS 5.3.0
includes new version of OpenSSL that resolves this.
Fixed in Fabric OS 5.3.0
Incorrect time in Web Tools Switch Health report. Fixed in Fabric OS 5.3.0
IncorrectF_PortbehaviorwhenRXsideofthecableisdisconnected,
while the TX side is still inserted.
Fixed in Fabric OS 5.3.0
Installation of PKI c erticate is delayed on a ny switch on which
installation is attempted due to timing of the startup function.
Fixed in Fabric OS 5.3.0
The last character of cong uploaded Banner (via bannerset” CLI
com
mand) will disappear when performing a configupload
followed by configdownload.
Fixed in Fabric OS 5.3.0
When connected to i10k Director in open mode, an RSCN received
from the i10k was not immediately forwarded.
Fixed in Fabric OS 5.3.0
HP StorageWorks Fabric OS 5.3.1 release notes
23