HP StorageWorks Fabric OS 5.3.1 release notes (AA-RWEYI-TE, March 2008)

NOTE:
The B-Series MP Router Blade (for use with the 4/256 Director only) must run Fabric OS 5.1.0d or later.
Note that the Core Switch 2/64 does not support the B-Series MP Router Blade.
Firmware upgrade instructions
IMPORTANT:
HP strongly recommends that users upgrade to Fabric OS 5.3.1 as soon as possible (particularly if your
model is the Brocade 4Gb SAN Switch for HP c-Class BladeSystem and you are currently running a
version of Fabric OS earlier than 5.3.0b).
To access the latest Fabric OS 5.3.1 rmware , conguration les, and MIB les, go to the following HP
web site: h
ttp://www.hp.com/go/san.
CAUTION:
Install port blades like the HP StorageWorks 4/48 SAN D irector Blade (FC4 –48) only after upgrading
to F abric OS 5.2.0a or later.
HP does not support directly upgrading from more than two previous releases. For example, upgrading
from Fabric OS 5.1.x to 5.3.1 is supported, but upgrading from Fabric OS 5.0.x or a previous release
directly to 5.3.1 is not.
Upgrading a switch from Fabric OS 5.0.x or a previous release to 5.3.0 requires a two-step process:
rst upgrade to Fabric OS 5.1. x or 5.2.x and then upgrade to 5.3.1.
The following conditions must be met before upgrading to Fabric OS 5.3.1:
Device-based routing must not be in use, otherwise the upgrade will fail. You can use the
aptPolicy c om m a nd to verify the routing policy.
Chassis conguration options 3 and 4 are no longer suppor ted for the 4/256 SAN Director.
Fabric OS 5.1.1 supports a maximum MTU value of 2284. However, Fabric OS 5.2.1x and 5.3x
supportanMTUvalueofupto2348. PriortodowngradingtheFabricOSto5.1.1youmust
change the MTU size less than or equal to 2284.
If the conguration of the target unit has an MTU value greater than 2284, the FCIP tunnels
will not go online after rmware downgrade.
CAUTION:
If the 4/256 SAN Director integrates the FC4–48 Blade or any new software features in Fabric OS
5.2.0a, such as FCR trunking, you cannot downgrade below Fabric OS 5.2.0a. If you want to do so, you
must (a) remove these features, (b) physically remove the Blade, and then (c) downgrade the rmware.
For any other new software features or increased scalability limits suppor ted by Fabric OS 5.3.1,
downgr
ade will be disruptive and require cold reboot.
AFabricOS5.3.1conguration le cannot be used on the same switch after the switch has been
downgraded to rmwar e version 5.1.x or 5.2.x.
When you downgrade to Fabric OS 5.0.x, you must also remove additional 5.1.x features and
any in
stalled B-Series MP Router blades.
HP StorageWorks Fabric OS 5.3.1 release notes
9