Brocade Fabric OS Documentation Updates - Supporting Fabric OS v7.0.x (53-1002165-05, March 2012)

Fabric OS Documentation Updates 7
53-1002165-05
Chapter
4
Fabric OS Command Reference
In this chapter
Documentation Updates for Fabric OS v7.0.1 . . . . . . . . . . . . . . . . . . . . . . . . . 7
Documentation Updates for Fabric OS v7.0.0 . . . . . . . . . . . . . . . . . . . . . . . . . 9
Documentation Updates for Fabric OS v7.0.1
The updates in this section are for the Fabric OS Command Reference, publication number
53-1002447-01, published December 15, 2011.
The note on page xxi in the Preface includes an incorrect platform reference. The note should read:
portCfgOctetSpeedCombo - Not supported on the Brocade 6505; supported on the Brocade FC8-32E
and FC8-48E port blades only with the default combination.
portCfgDPort
Add the following configuration option to the portCfgDport --enable command:
portcfgdport --enable [slot/]port_list dwdm
Skips the optical loopback test when you run the D_Port diagnostics over a Dense
Wavelength Division Multiplexing (DWDM) link or any third party equipment that
connects two switches.
D_Port functionality is only available on 16Gbit-capable platforms with 16Gb SFPs and 10Gb FC SFPs.
portCfgShow
On page 688, add the following descriptions under the "Non-GbE port displays" section:
Octet Speed Combo: Displays the current octet speed combo setting. This parameter is set by the
portCfgOctetSpeed command. In unsupported platforms, this display is not
shown
D-Port over DWDM Displays ON when the D_P ort is configured over a DWDM link. This parameter is
set by portCfgDPort command and displays only if portcfgDPort is configured
with the dwdm option.
portStatsShow
This command has been updated to include the following counters. These counters are supported only
on Condor3-based platforms and display only on these platforms
er_single_credit_loss