Brocade Fabric OS Documentation Updates - Supporting Fabric OS v7.0.x (53-1002165-05, March 2012)

Fabric OS Documentation Updates 13
53-1002165-05
Chapter
5
Fabric OS Encryption Guide Supporting LKM
In this chapter
The updates in this chapter are for the Fabric OS Encryption Administrator’s Guide Supporting
NetApp Lifetime Key Manager (LKM) Environments, publication number 53-1002160-02,
published June 2011.
Documentation updates for LKM
Chapter 3, Configuring Brocade Encryption Using CLI
Failover/failback policy configuration
A correction has been made to heartbeat values for the following:
Heartbeat misses—The range is 3-14 in integer increments only.
Heartbeat timeout—The range is 2-9 seconds in integer increments only.
Chapter 5, Best Practices and Special Topics
Key Vault Best Practices
When encrypted disk LUNs are to be configured or moved to an Encryption Group that uses a
different key vault, make sure to decommission the encrypted LUNs from the old Encryption Group.
Chapter 6, Maintenance and Troubleshooting
Manually synchronizing the security database
This operation can resolve problems with master key propagation (and connectivity issues between
peer node encryption engines in an encryption group). The synchronization occurs every time this
command is executed regardless of whether or not the security database was synchronized across
all nodes in the encryption group.
Use the - -sync -securitydb command to distribute the security database from the group leader
node to all member nodes. This command is valid only on the group leader.
In scenarios where this master key propagation issue still persists, exporting the master key to a
file and recovering it resolves the issue. To do this, use the following commands: