Brocade Fabric OS Documentation Updates - Supporting Fabric OS v7.0.x (53-1002165-05, March 2012)

Fabric OS Documentation Updates 41
53-1002165-05
Chapter
15
Brocade 6510 Hardware Reference Manual
In this chapter
The updates in this chapter are for various hardware manuals.
Chapter 2, Brocade 6510 Installation and Configuration. . . . . . . . . . . . . . . 41
Appendix A, Brocade 6510 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Chapter 2, Brocade 6510 Installation and Configuration
Under the heading “Local time synchronization” on page 11, replace the paragraph that says:
If the active NTP server configured is IPv6, then distributing the same in the fabric will not be
possible to switches earlier than v5.3.0 because IPv6 is supported for Fabric OS version 5.3.0
and later. The default value LOCL will be distributed to pre-5.3.0 switches.
with the following paragraph:
If the active NTP server configured is IPv6, then distributing the same information in the fabric
will not be possible to switches earlier than v5.3.0 because IPv6 is supported for Fabric OS
version 5.3.0 and later. The default value LOCL will be distributed to pre-5.3.0 switches.
Under the heading “Setting the date” on page 11, replace the text for step 2 with the following:
2. Enter the date command, using the following syntax (the double quotation marks are required):
date "mmddHHMMyy"
Appendix A, Brocade 6510 Specifications
Under the heading “General specifications” on page 33, replace the information in Table 9 in the
Description column for the Switching capacity information with the following information.
Specification Description
Switching capacity An aggregate switching capacity of 420 million frames per second (for
Class 2, Class 3, and Class F frames for the 48 port chassis)