Brocade Fabric OS v7.0.2e Release Notes v1.0

Fabric OS v7.0.2e Release Notes v1.0 Page 50 of 53
Defect ID:
DEFECT000410236
Technical Severity:
Medium
Summary:
EE monitors in VF environment with duplicate PID/SID on same ASIC do not function
Symptom:
Create a logical switch and install EE monitors on the ports (same asic) of both default and logical
switch having same sid/pid, then run traffic and the EE monitor counters do not increament as
expected.
Probability:
Low
Feature:
FOS Software
Function:
Virtual Fabric
Reported In Release:
FOS6.3.2
Service Request ID:
752195
Defect ID:
DEFECT000411644
Technical Severity:
Medium
Summary:
When executed on BR6510/BR06505, portloopbacktest command always uses 16G mode,
regardless of port speed specified.
Symptom:
On BR6510/BR6505, "portloopbacktest -spd_mode 8" does not indicate the test is run in 8G
speed. Same is true for 4G and other valid "spd_mode" options
Probability:
High
Feature:
16G Platform Services
Function:
FOS Kernel Drivers
Reported In Release:
FOS7.0.1
Service Request ID:
754811
Defect ID:
DEFECT000412938
Technical Severity:
Medium
Summary:
Fabric Watch erroneously reporting a "build fabric"
Symptom:
On a busy switch, Fabric Watch falsely reports "build fabric" event.
Probability:
Low
Feature:
FOS Software
Function:
System Performance
Reported In Release:
FOS6.4.1
Service Request ID:
756411
Defect ID:
DEFECT000414360
Technical Severity:
High
Summary:
"Redirect zone update failed" when issuing 'cryptocfg --commit'
Symptom:
After adding initiator to target container is performed, executing the 'cryptocfg --commit' command
results in the following failure: "Operation succeeded. Commit operation completed successfully,
Redirect zone update failed. Please retry commit operation." Additional attempts at commit do
not result in redirect zone creation success, and container remains offline.
Probability:
Medium
Feature:
Data Security
Function:
Disk Encryption
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000419620
Technical Severity:
High
Summary:
An hafailover, hareboot or firmwaredownload may cause unused ports with a ASIC register being
zeroed out
Symptom:
If frames are queued to the unused ports, credit is permanently lost and observe busy buffer
condition on the port
Probability:
Low
Feature:
8G ASIC Driver
Function:
C2 ASIC driver
Reported In Release:
FOS7.0.0
Service Request ID:
1033850
Defect ID:
DEFECT000419937
Technical Severity:
High
Summary:
Fabric LOGO is not clearing out the stale FCID logins on Brocade Access Gateway. Customer is
seeing "duplicate Alpa" error messages from fabric.
Symptom:
Duplicate Alpa error message is being seen on Brocade AG when LPAR move is executed. This
move re-assigns virtual WWPNs to another physical host.
Probability:
High
Feature:
FOS Software
Function:
Access Gateway
Reported In Release:
FOS6.4.2
Service Request ID:
1087072,1087072