Defect ID:
DEFECT000461699
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Security
Reported In Release:
FOS7.1.0
Technology Area:
Encryption
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
CVLC might crash during host login to VT or crypto configuration change.
Condition:
Issue will only be seen on Brocade Encryption Switch or FS8-18 blade. Only with higher ITL count
configuration, when crypto config change is done through “cryptocfg –commit” command, CVLC
might crash due to a race condition between host login and internal command timeout.
Defect ID:
DEFECT000462116
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Management
Reported In Release:
FOS7.0.0
Technology Area:
Platform Services
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
Director rebooted: CPs lost heartbeat and active CP was reset, standby CP panicked during take over.
Condition:
Port blade hardware failure may trigger loss of heartbeat (between two CPs)
Recovery:
Switch is recovered after reboot; replace bad port blade to prevent re-occurrence.
Defect ID:
DEFECT000463819
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Traffic Management
Reported In Release:
FOS7.0.2
Technology Area:
FC-FC routing
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
Class 2 GPN_FT queries may fail with excessive targets (127 targets) in the fabric.
Condition:
Occurs if any class 2 query response spans more than one FC frame and the end to end credit is
unable to accommodate the response
Workaround:
Reduce the number of devices zoned together so that the number of FC frames responded by the
switch for a name server query does not exceed the credit configured at the device.
Else, increase the end-to-end credit configured at the device side to prevent failure in name server
query.
Recovery:
Increase the credits configured at the device side.
Defect ID:
DEFECT000465422
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS7.2.0
Technology Area:
Diagnostic Port (D_Port)
Closed In Release(s):
FOS7.2.1(Fixed)
Symptom:
When enable D-port test through BNA, for F-port to HBA links in automatic mode, failure reason
code is not shown correctly in case of test failure.
Condition:
Occurs when enable D-port Test for F-port to HBA links in Automatic mode, through BNA only.
Workaround:
Enable D-port Test through CLI to display the appropriate Failure Reasons.